Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Angew Chem Int Ed Engl ; 63(8): e202316706, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38126129

RESUMEN

Diarylethene molecular photoswitches hold great fascination as optical information materials due to their unique bistability and exceptional reversible photoswitching properties. Conventional diarylethenes, however, rely on UV light for ring-closure reactions, typically with modest yields. For practical application, diarylethenes driven by visible lights are preferred but achieving high ring-closure reaction yield remains a significant challenge. Herein, we synthesized a novel all-visible-light-driven photoswitch, TPAP-DTE, by facilely endcapping the dithienylethene (DTE) core with triphenylamine phenyl (TPAP) groups. Owing to the electron-donating conjugation effect of TPAP, the open-form TPAP-DTE responds strongly to short-wavelength visible lights with considerable photocyclization quantum yields and molar absorption coefficient. Upon 405 nm visible-light irradiation, TPAP-DTE achieves a ring-closure reaction yield exceeding 96.3 % (confirmed by both nuclear magnetic resonance spectroscopy and high-performance liquid chromatography). Its ring-opening reaction yield is 100 % upon irradiation with long-wavelength visible light. TPAP-DTE could be regarded as a bidirectional "quasi"-quantitative conversion molecular switch. Furthermore, TPAP-DTE exhibits robust fatigue resistance over 100 full photoswitching cycles and great anti-aging property under 85 °C and 85 % humidity for at least 1000 h. Consequently, its rewritable QR-code, multilevel data storage, and anti-counterfeiting/encryption applications are successfully demonstrated exclusively using visible lights, positioning TPAP-DTE as a highly promising medium for information recording.

2.
Kaohsiung J Med Sci ; 38(4): 347-356, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35005835

RESUMEN

Allergic rhinitis (AR) is a chronic inflammatory disease of the nasal mucosa. M2 macrophage polarization can reduce inflammation and repair tissue injury during AR development. Studies have substantiated the involvement of miRNAs in AR pathogenesis. Herein, the molecular mechanism of miR-214-3p in AR development was explored. To mimic the AR environment, ovalbumin (OVA) was used to treat macrophages. MiR-214-3p and glycogen synthase kinase 3 beta (GSK3B) expression in nasal mucus tissues and macrophages was assessed by RT-qPCR. The M2 phenotypic signature of CD206 in macrophages was assessed by flow cytometry. The protein expression of GSK3B and M2 macrophage markers (ARG-1 and IL-10) was evaluated by western blotting. The correlation between miR-214-3p and GSK3B was validated by a luciferase reporter assay. We found that miR-214-3p was overexpressed in macrophages and nasal mucus tissues from AR patients. MiR-214-3p facilitated M2 polarization of macrophages upon OVA stimulation. Mechanistically, miR-214-3p targeted the GSK3B 3' untranslated region in macrophages. In addition, GSK3B was downregulated in macrophages and nasal mucus tissues from AR patients. In rescue assays, GSK3B downregulation reversed the inhibitory effects of miR-214-3p silencing on M2 polarization of macrophages treated with OVA. Overall, miR-214-3p facilitates M2 macrophage polarization by targeting GSK3B.


Asunto(s)
MicroARNs , Regulación hacia Abajo , Glucógeno Sintasa Quinasa 3 beta/genética , Glucógeno Sintasa Quinasa 3 beta/metabolismo , Humanos , Activación de Macrófagos/genética , Macrófagos/metabolismo , MicroARNs/genética , MicroARNs/metabolismo
3.
BMC Oral Health ; 21(1): 636, 2021 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-34893053

RESUMEN

BACKGROUND: To compare the accuracy of photogrammetry, intraoral scanning and conventional impression techniques for complete-arch implant rehabilitation. METHODS: A master cast containing 6 implant abutment replicas was fabricated. Group PG: digital impressions were taken 10 times using a photogrammetry system; Group IOS: intraoral scanning was performed to fabricate 10 digital impressions; Group CNV: splinted open-tray impression technique was used to fabricate 10 definitive casts. The master cast and conventional definitive casts were digitized with a laboratory reference scanner. For all STL files obtained, scan bodies were converted to implant abutment replicas using a digital library. The accuracy of a digitizer was defined by 2 main parameters, trueness and precision. "Trueness" was used to describe the deviation between test files and reference file, and "precision" was used to describe the closeness between test files. Then, the trueness and precision of three impression techniques were evaluated and statistically compared (α = 0.05). RESULTS: The median trueness was 24.45, 43.45 and 28.70 µm for group PG, IOS and CNV; Group PG gave more accurate trueness than group IOS (P < 0.001) and group CNV (P = 0.033), group CNV showed more accurate trueness than group IOS (P = 0.033). The median precision was 2.00, 36.00 and 29.40 µm for group PG, IOS and CNV; Group PG gave more accurate precision than group IOS (P < 0.001) and group CNV (P < 0.001), group CNV showed more accurate precision than IOS (P = 0.002). CONCLUSIONS: For complete-arch implant rehabilitation, the photogrammetry system showed the best accuracy of all the impression techniques evaluated, followed by the conventional impression technique, and the intraoral scanner provided the least accuracy.


Asunto(s)
Implantes Dentales , Técnica de Impresión Dental , Diseño Asistido por Computadora , Humanos , Imagenología Tridimensional , Modelos Dentales , Fotogrametría
4.
J Prosthet Dent ; 120(3): 389-395, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29703675

RESUMEN

STATEMENT OF PROBLEM: Although computer-aided design and computer-aided manufacturing (CAD-CAM) complete removable dental prostheses (CRDPs) have gained popularity, conventional impressions are still common for CAD-CAM CRDP treatment. These need to be digitized and converted into virtual edentulous casts with a laboratory impression scan protocol during prosthesis fabrication. How this can best be accomplished is unclear. PURPOSE: The purpose of this in vitro study was to compare the accuracy and reproducibility of virtual edentulous casts created by a dental laboratory laser scanner and a cone beam computed tomography (CBCT) scanner with a digitized master cast. MATERIAL AND METHODS: A master cast was digitized as the virtual reference cast. Ten polyvinyl siloxane impressions were made on the master cast and scanned with the dental laboratory laser scanner and CBCT scanner. The impressions were sprayed with antiglare spray and rescanned. Four groups of virtual study casts (N=40) were created from the impression scans. All virtual study casts and the reference cast were registered with surface-matching software, and the root mean square (RMS) values (representation of overall accuracy) and percentage of measurement data points within 1 standard deviation (SD) of mean RMS values (%, representation of overall reproducibility) among the 4 study groups were measured. Additionally, 95 numeric distance differences (representation of accuracy at each region) were measured in 5 distinct regions: the apex of the denture border, 6 mm from denture border, crest of the ridge, palate, and posterior palatal seal. The repeated-measures ANOVA and post hoc test (t grouping) were used to determine statistical differences (α=.05). RESULTS: The laboratory scanner group had a significantly larger RMS value (4.0 ±0.3 µm, P<.001) and smaller percentage of measurement data points within 1 SD of mean RMS value (77.5 ±1.0%, P<.001). The RMS values between the CBCT scanner (1.2 ±0.3 µm) and CBCT scanner-spray (1.1 ±0.2 µm) groups were not significantly different (P=.968), and the percentage of measurement data points within 1 SD of mean RMS values (90.1 ±1.1% versus 89.5 ±0.8%) were also not significantly different (P=.662). The numeric distance differences across 5 regions were affected by the scanning protocols (P<.001). The laboratory scanner and laboratory scanner-spray groups had significantly higher numeric distance differences at the apex of the denture border and crest of the ridge regions (P<.001). CONCLUSIONS: The CBCT scanner created more accurate and reproducible virtual edentulous casts, and the antiglare spray only significantly improved the accuracy and reproducibility of virtual edentulous casts created by the dental laboratory laser scanner. The accuracy of the virtual edentulous casts was different across 5 regions and was affected by the scanning protocols.


Asunto(s)
Técnica de Colado Dental , Técnica de Impresión Dental , Diseño de Dentadura/métodos , Dentadura Completa , Diseño Asistido por Computadora/normas , Tomografía Computarizada de Haz Cónico , Técnica de Colado Dental/normas , Técnica de Impresión Dental/normas , Diseño de Dentadura/normas , Dentadura Completa/normas , Humanos , Reproducibilidad de los Resultados
5.
J Prosthet Dent ; 118(6): 712-716, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28456371

RESUMEN

This article proposes a 2-visit clinical protocol to manage prosthodontic complications resulting from limited prosthetic space, using a monolithic, multichromatic computer-aided design and computer-aided manufacturing (CAD-CAM) acrylic resin implant overdenture. The advantages and limitations of using this approach are outlined and discussed.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Prótesis de Recubrimiento , Boca Edéntula/rehabilitación , Boca Edéntula/cirugía , Complicaciones Posoperatorias/terapia , Humanos
6.
Clin Nephrol ; 87(6): 293-300, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28332473

RESUMEN

OBJECTIVE: To analyze the correlations of renal tissue elastography with clinical biochemical indicators and pathological changes in patients with chronic kidney disease (CKD) as well as to explore the potential for renal tissue elastography as a new, noninvasive method for the dynamic monitoring of renal disease progression, efficacy assessment, and prognosis evaluation. METHODS: Patients admitted to the Department of Nephrology of the First Affiliated Hospital of China Medical University from August 2014 to January 2015 who had undergone renal biopsies were selected. A total of 113 patients with CKD and 16 healthy controls were enrolled in this study, including 61 males and 52 females. In total, 23 cases of IgA nephropathy, 39 cases of membranous nephropathy, 15 cases of minimal-change nephropathy (MCN), and 7 cases of focal segmental glomerulosclerosis were included. The Young's moduli (YM) of the renal cortex and medulla were measured using an AixPlorer Doppler ultrasound with full digital color from Supersonic Imagine. The correlations between the YM of renal tissue and clinical biochemical indicators of blood and urine and the differences in Young's moduli among the different pathological changes in the patients with CKD were analyzed. RESULTS: The YM of the CKD patients was significantly higher than that of the control group (p < 0.05), and the YM of the renal cortex and medulla gradually increased with the progression of CKD. The YM of the renal cortex in the stage-G5 CKD patients was significantly higher than that of the CKD patients in stages G1 - G3 (p < 0.05). The YM of the renal medulla of the CKD patients in stages G3 - 5 was significantly higher than that of the CKD patients in stages G1 - G2. On univariate analysis, the YM of the renal cortex was correlated with systolic blood pressure, serum creatinine, cystatin C, serum albumin, serum phosphorus, calcium and phosphorus products, uric acid, iPTH, urinary N-acetyl-glucosaminidase (NAG), eGFR, and hemoglobin levels. And the YM of the renal medulla was correlated with systolic blood pressure, serum creatinine, serum albumin, uric acid, iPTH, urinary microalbumin (MA), urinary NAG, and hemoglobin levels. On multivariate analysis, serum cystatin C (ß = 0.485, p = 0.018) and uric acid (ß = 0.418, p = 0.039) levels were independently correlated with the YM of the renal cortex, while serum creatinine (ß = 0.380, p = 0.019) and uric acid (ß = 0.482, p = 0.004) levels, as well as smoking (ß = 0.337, p = 0.009), were independently correlated with the YM of the renal medulla. The YMs of the renal cortex in patients with membranous nephropathy and IgA nephropathy were significantly higher than those in the patients with CN (p < 0.05). The YM of the renal cortices of the patients in phases IV and V of IgA nephropathy based on the Lee grading system were significantly higher than those of the patients in phases II and III (p < 0.05). According to the Oxford classification for IgA nephropathy, the Young's moduli of the renal cortex and medulla in T1 and T2 patients were significantly higher than those in T0 patients (p < 0.05). The YM of the renal cortex and medulla showed no statistically-significant differences among the different stages of membranous nephropathy. CONCLUSIONS: The YM of the renal cortex and medulla are associated with the progression of renal insufficiency, and renal ultrasound elastography shows promise as a new means of assessing the stage of CKD. Renal ultrasound elastography is expected to become a new, noninvasive method for the early diagnosis of CKD and the dynamic monitoring of disease progression as well as the assessment of efficacy and prognosis.
.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Riñón , Insuficiencia Renal Crónica , Presión Sanguínea , Femenino , Humanos , Riñón/diagnóstico por imagen , Riñón/fisiopatología , Masculino , Insuficiencia Renal Crónica/diagnóstico por imagen , Insuficiencia Renal Crónica/epidemiología , Insuficiencia Renal Crónica/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...